Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
Starting with Windows XP, you can initialize WPP tracing in a user-mode DLL by calling the WPP_INIT_TRACING macro to initialize WPP software tracing.
To avoid errors, use the following method.
Call the WPP_INIT_TRACING macro in the DllMain function of the DLL.
If your DLL is written in C, add a #define statement for WPP_OLDCC to your source code. Put the definition before the #include statement for the trace message header (.tmh) file. The WPP_OLDCC definition is required only for C code. It is not required for C++.
For example:
#define WPP_OLDCC #include "init.tmh"
You cannot initialize WPP software tracing in a DllMain function on Microsoft Windows 2000. Because WPP runs as part of a service on Windows 2000, initializing software tracing generates a remote procedure call, which is prohibited during DLL initialization.